Symbol 00995566 Certification RCM compliance mark c UL us – Listed (OL) CE marking (see declaration of conformity) As per EU EMC directive As per EU rohs directive KC characters KC EMC Note on materials rohs-compliant Measured variable Flow rate Temperature Flow direction Unidirectional P1 -> P2 Method of measurement Flow rate: vortex Temperature: PT1000 Flow measuring range start value 1.8 l/min Flow measuring range end value 32 l/min Temperature measuring range start value 0 °c Temperature measuring range end value 90 °c Operating pressure 0 bar … 12 bar Information on operating pressure Max. 12 bar at 40°c Max. 6 bar at 100 °c Operating medium Liquid media Water Neutral liquids Information on operating and pilot media Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured. Temperature of medium 0 °c … 90 °c Ambient temperature 0 °c … 50 °c Nominal temperature 23 °c Accuracy of flow rate ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS Accuracy of temperature in ± °c 2 °c Repetition accuracy of flow rate value < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS Temperature co-efficient margin in ± %FS/K Typ. ±0.05% FS/K Switching output 2 x PNP or 2 x NPN switchable Switching function Window comparator Threshold value comparator Freely programmable Switching element function N/C contact/N/O contact switchable Max. output current 100 mA
Analog output 0 – 10 V
4 – 20 mA
1 – 5 V
Flow characteristic curve, start value 0 l/min
Flow characteristic curve, end value 32 l/min
Temperature characteristic curve start value 0 °c
Temperature characteristic curve end value 100 °c
Max. load resistance of current output 500 Ohm
Min. load resistance of voltage output 15 kOhm
Short-circuit protection yes
Overload protection Available
Protocol IO-Link®
IO-Link®, protocol version Device V 1.1
IO-Link®, profile Smart sensor profile
IO-Link®, function classes Binary data channel (BDC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link®, communication mode COM2 (38,4 kBd)
IO-Link®, SIO mode support Yes
IO-Link®, port class A
IO-Link®, process data width OUT 0 Byte
IO-Link®, process data width IN 5 Byte
IO-Link®, process data content IN 1 bit BDC (temperature monitoring)
1 bit BDC (volume monitoring)
14 bit PDV (flow measurement)
14 bit PDV (temperature measurement)
2 bit BDC (flow monitoring)
IO-Link®, service data contents IN 32 bit volume measurement
IO-Link®, minimum cycle time 5 ms
IO-Link®, data memory required 500 byte
DC operating voltage range 18 V … 30 V
Reverse polarity protection for all electrical connections
Electrical connection 5-pin
A-coded
M12x1
Plug, straight
Max. cable length 20 m for IO-Link® operation
30 m
Mounting position Any
Fluid connector Internal thread G1/2
Product weight 400 g
Housing material PA-reinforced
Materials in contact with the media EPDM (peroxide)
ETFE
Stainless steel
PA6T/6I-reinforced
Displayable unit(s) US gal
US gal/min
cft
cft/min
l
l/h
l/min
m3
°c
°c
°F Degree of protection IP65
Corrosion resistance class (CRC) 3 – high corrosion stress
Additional information